Occupancy data is represented either in hours or percentage of a day (24 hours). A floor/zone/group/device-based graph and time-based graph are displayed based on the filter selection in the descending order of usage. By default, the data will be represented in Hours and floor-based and time-based graphs of the building shall be displayed. Using filters, a user can drill down the data to Floor, Zone, Group, or Sensor level. The building/floor/zone /group /sensor-based graph will display the total occupancy duration of the building/floor/zone/group respectively and the component(s) with maximum and minimum occupancy along with their duration.
There is the option to view data in either the total duration of usage or as a percentage. Percentage of occupancy shall be computed by considering the duration for which the sensor detected motion and the time frame for which this data is to be represented.
If a floor is selected from the filter, data about the floor's total hours of occupancy, most occupied zone(s)of that floor and its duration of occupancy, least occupied zone(s), and its duration of occupancy shall be displayed. If a zone is selected from the filter and
- the groups tab is chosen, data about the zone's total hours of occupancy, most occupied group(s) of that zone and its duration of occupancy, least occupied group(s), and its duration of occupancy shall be displayed
- the sensors tab is chosen, data about the zone's total hours of occupancy, most occupied sensor(s) of that zone and its duration of occupancy, least occupied sensor(s) and its duration of occupancy shall be displayed
If a group is selected from the filter, data about the group's total hours of occupancy, most occupied sensor(s)of that group and its duration of occupancy, least occupied sensor(s) and its duration of occupancy shall be displayed. If a sensor is selected from the filter, only its time-based analysis graph will be shown.
A floor/zone/group/sensor shall be chosen from the graph or from the filter to view its time-based analysis and zone/group/sensor-based analysis.
The limit of occupancy duration shall be indicated for each floor/zone/group/sensor in the respective graphs as configured in Report settings.
You can also visit the following sections for more information:
To know on how the values are calculated for occupancy reports?, click here
To know the purpose of Energy Consumption Reports, click here
Was this article helpful?
That’s Great!
Thank you for your feedback
Sorry! We couldn't be helpful
Thank you for your feedback
Feedback sent
We appreciate your effort and will try to fix the article